Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
EuroIntervention ; 20(7): e445-e452, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38562068

RESUMO

BACKGROUND: Technological and surgical approaches to carotid artery stenting (CAS) have evolved. Modern randomised controlled trials comparing CAS and carotid endarterectomy (CEA) are limited, and information about updated post-intervention outcomes are mostly from retrospective, small studies. AIMS: This study aims to compare the 30-day outcomes of stroke, transient ischaemic attack (TIA), acute myocardial infarction (AMI) and death with propensity-matched groups of CEA and CAS in asymptomatic and symptomatic patients over a recent study period of new CAS technologies and approaches. METHODS: A retrospective, observational, multicentre analysis was conducted including consecutive symptomatic and asymptomatic patients treated with either primary CEA or CAS for internal carotid artery stenosis, between 2015 and 2022. Patients were propensity score-matched based on comorbidities and assessed according to symptom status. Primary endpoints include composite ipsilateral stroke, TIA, AMI and death within 30 days. Secondary endpoints include technical success and length of hospital stay. RESULTS: From a cohort of 1,110 patients, propensity matching produced 269 distinct treatment pairs (n=538). Most patients were asymptomatic (n=456, 85%). All 6 strokes were minor (CEA=2; CAS=4) and registered among asymptomatic patients. One AMI (CEA) and 1 patient death (CAS) were reported among symptomatic patients. Composite stroke/AMI/death were not significantly different between both types of symptom status and both revascularisation techniques (p=0.44 and p=1, respectively). Technical success was 100%. The length of hospital stay was significantly shorter in asymptomatic patients treated with CAS compared to those treated with CEA (p=0.05), but no difference was registered among symptomatic patients (p=0.32). CONCLUSIONS: Propensity-matched analysis suggests that CAS has similar postprocedural outcomes for stroke, AMI and death at 30 days compared to CEA.


Assuntos
Estenose das Carótidas , Endarterectomia das Carótidas , Ataque Isquêmico Transitório , Infarto do Miocárdio , Acidente Vascular Cerebral , Humanos , Endarterectomia das Carótidas/efeitos adversos , Estenose das Carótidas/cirurgia , Ataque Isquêmico Transitório/etiologia , Estudos Retrospectivos , Pontuação de Propensão , Resultado do Tratamento , Stents , Acidente Vascular Cerebral/etiologia , Infarto do Miocárdio/etiologia , Artérias Carótidas , Fatores de Risco
2.
Bioengineering (Basel) ; 11(2)2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38391683

RESUMO

There is currently a shift in surgical training from traditional methods to simulation-based approaches, recognizing the necessity of more effective and controlled learning environments. This study introduces a completely new 3D-printed modular system for endovascular surgery training (M-SET), developed to allow various difficulty levels. Its design was based on computed tomography angiographies from real patient data with femoro-popliteal lesions. The study aimed to explore the integration of simulation training via a 3D model into the surgical training curriculum and its effect on their performance. Our preliminary study included 12 volunteer trainees randomized 1:1 into the standard simulation (SS) group (3 stepwise difficulty training sessions) and the random simulation (RS) group (random difficulty of the M-SET). A senior surgeon evaluated and timed the final training session. Feedback reports were assessed through the Student Satisfaction and Self-Confidence in Learning Scale. The SS group completed the training sessions in about half time (23.13 ± 9.2 min vs. 44.6 ± 12.8 min). Trainees expressed high satisfaction with the training program supported by the M-SET. Our 3D-printed modular training model meets the current need for new endovascular training approaches, offering a customizable, accessible, and effective simulation-based educational program with the aim of reducing the time required to reach a high level of practical skills.

3.
Vasc Endovascular Surg ; 58(2): 223-229, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37641383

RESUMO

Spinal cord ischemia leading to paraplegia is a rare, life-limiting complication of acute type B aortic dissection. We report a case of spinal cord ischemia occurred in a young woman treated with endovascular scissor technique in urgent setting. The patient had an uneventful post-procedural course. After 4 months, computed tomography angiography confirmed false lumen reperfusion and major symptoms were regressed. In selected cases, this procedure is a tool to improve false lumen perfusion in type B dissections, and demonstrated to be helpful in our case of spinal cord ischaemia.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Isquemia do Cordão Espinal , Feminino , Humanos , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Isquemia do Cordão Espinal/diagnóstico por imagem , Isquemia do Cordão Espinal/etiologia , Paraplegia/etiologia , Estudos Retrospectivos , Medula Espinal
4.
Angiology ; 75(4): 314-322, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36891765

RESUMO

The present study reported the outcomes of different treatments for innominate artery (IA) atherosclerotic stenosis or occlusion. We performed a systematic review of the literature (4 database searched; last search February 2022), including articles with ≥5 patients. We performed meta-analyses of proportions for different postoperative outcomes. Fourteen studies were included (656 patients; 396 underwent surgery, 260 endovascular procedures). IA lesions were asymptomatic in 9.6% (95% CI 4.6-14.6). Overall estimated technical success (TS) rate was 91.7% (95% CI 86.9-96.4); weighted TS rate was 86.8% (95% CI 75-98.6) in the surgical group (SG), 97.1% (95% CI 94.6-99.7) in the endovascular group (EG). Postoperative stroke in SG was 2.5% (95% CI 1-4.1) and 2.1% in EG (95% CI .3-3.8). Overall, 30-day occlusion was estimated .9% (95% CI 0-1.8) in SG and .7% (95% CI 0-1.7) in EG. Thirty-day mortality was 3.4% (95% CI .9-5.8) in SG and .7% (95% CI 0-1.7) in EG. Estimated mean follow-up after intervention was 65.5 months (95% CI 45.5-85.5) in SG and 22.4 months (95% CI 14.72-30.16) in EG. During follow-up, restenosis in SG were 2.8% (95% CI .5-5.1) and 16.6% (95% CI 5- 28.1) in EG. In conclusion, the endovascular approach seems to offer good short to mid-term outcomes, but with a higher rate of restenosis during follow-up.


Assuntos
Aterosclerose , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Constrição Patológica/cirurgia , Tronco Braquiocefálico/cirurgia , Aterosclerose/terapia , Resultado do Tratamento , Stents
5.
Artigo em Inglês | MEDLINE | ID: mdl-38037721

RESUMO

The objective of these Guidelines is to provide recommendations for the classification, indication, treatment and management of patients suffering from aneurysmal pathology of the visceral and renal arteries. The methodology applied was the GRADE-SIGN version, and followed the instructions of the AGREE quality of reporting checklist. Clinical questions, structured according to the PICO (Population, Intervention, Comparator, Outcome) model, were formulated, and systematic literature reviews were carried out according to them. Selected articles were evaluated through specific methodological checklists. Considered Judgments were compiled for each clinical question in which the characteristics of the body of available evidence were evaluated in order to establish recommendations. Overall, 79 clinical practice recommendations were proposed. Indications for treatment and therapeutic options were discussed for each arterial district, as well as follow-up and medical management, in both candidate patients for conservative therapy and patients who underwent treatment. The recommendations provided by these guidelines simplify and improve decision-making processes and diagnostic-therapeutic pathways of patients with visceral and renal arteries aneurysms. Their widespread use is recommended.

6.
Ann Vasc Surg ; 88: 327-336, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35921977

RESUMO

BACKGROUND: Endovascular aortic repair (EVAR), currently the preferred treatment for abdominal aortic aneurysm (AAA), has been described also for penetrating aortic ulcers (PAU) of the infrarenal aorta. However, data on its performance in this particular setting are still sparse in the literature. Aim of this study is to compare patient clinical characteristics, aorto-iliac features, and post-operative outcomes between infrarenal PAU and AAA treated by standard EVAR. METHODS: In this retrospective observational case-control multicenter study, the patients treated for infrarenal PAU (G1) with EVAR in 2 high-volume European centers from January 2014 to December 2019 were prospectively entered into a dedicated database and retrospectively analyzed. A 4-fold control group (G2) of infrarenal AAA patients, homogeneous for age and gender, was also considered. Preoperative clinical characteristics, aorto-iliac features (rupture, aortic maximum diameter, proximal neck diameter and length, aortic bifurcation diameter, distance between the lowest renal artery and the aortic bifurcation [RA-AoBi], severe aortic calcification), technical success, 30-day (morbidity, reintervention, complications, mortality) and follow-up outcomes (freedom from reintervention [FFR] and survival) were compared in the 2 groups (chi square/Fisher exact test, t-student test, Mann-Whitney test, logistic regression and Kaplan-Meier analysis). RESULTS: Seventy-three patients (age 78 ± 7 years; male 84.9%) were included in G1 and 299 (age 78.4 ± 6.6 years; male 89.3%) in G2. At the time of diagnosis, G1 patients were more often symptomatic compared with G2 (odds ratio OR 10.21, 95% confidence interval CI 4.17-24.99, P < 0.001). At preoperative computed tomography angiography, G1 patients had more ruptures (OR 8.11, 95% CI 3.50-18.78, P < 0.001), smaller maximum diameter (OR 1.05, 95% CI 1.03-1.08, P < 0.001), longer and narrower proximal neck (OR 0.97, 95% CI 0.95-0.99, P = 0.020 and OR 1.47, 95% CI 1.32-1.64, P < 0.001, respectively) narrower aortic bifurcation (OR 1.34, 95% CI 1.24-1.45, P < 0.001), lower RA-AoBi (OR 1.09, 95% CI 1.07-1.12, P < 0.001), and more severe aortic calcification (OR 57, 95% CI 16-198, P = 0.001). Technical success (G1 98.6% vs G2 95.7% P = 0.320), 30-day morbidity (G1 2.7% vs G2 8.7% P = 0.133), reintervention (G1 2.7% vs G2 2.3% P = 0.691), complications (G1 6.8% vs G2 8% P = 0.737) and mortality (G1 1.4% vs 2% P = 0.720) were comparable in the 2 groups. The mean follow-up was 17.7 ± 16.4 months in G1 and 18.8 ± 15.1 in G2 (P = 0.576). Late FFR and survival were comparable in the 2 groups (1-year FFR: G1 94.8% vs G2 97.5%, P = 0.995; 1-year survival: G1 91.7% vs G2 92.3%, P = 0.960). CONCLUSIONS: Infrarenal PAU are more often symptomatic with a higher rupture rate compared to infrarenal AAA. Despite some negative anatomical characteristics (narrower aortic bifurcation, lower RA-AoBi, extensive calcification), the results of EVAR are extremely satisfactory in this setting, suggesting that endovascular exclusion could be considered a valid treatment for infrarenal PAU.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Úlcera Aterosclerótica Penetrante , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Implante de Prótese Vascular/efeitos adversos , Prótese Vascular , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Fatores de Risco
7.
Int Angiol ; 42(1): 9-18, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36534022

RESUMO

BACKGROUND: The purpose is to evaluate the follow-up outcomes after femoro-popliteal stenting with Cook Zilver PTX in a multicenter experience. METHODS: Collected data from four Units were retrospectively joined and analyzed considering Zilver PTX deployed from August 2009 according to the instruction for use. Patient demographics, preoperative comorbidities, Rutherford classification, arterial characteristics and stent data were considered. Target lesion revascularization (TLR) was defined as reintervention performed for ≥50% diameter stenosis after recurrent clinical symptoms. Primary outcome was the freedom from TLR (ffTLR) and its risk factors. Secondary outcomes were primary patency (PP) of the stent, amputation-free survival (AFS) and their risk factors. RESULTS: Considering 203 patients (mean age: 73.5 years ±10.6; male: 66.5%) and 263 stents (median 2 stents/patient, range 1-5stent/patient), chronic limb-threatening ischemia (CLTI) affected 154 patients (75.9%). The length of the treated lesion was <120 mm in 99 (48.8%), ≥120 mm and <200 mm in 65 (32%) and ≥200 mm in 39 (19.2%) cases, respectively; the reference vessel mean diameter was 5.5±0.7 mm; chronic total occlusion was treated in 153 (75.4%) patients, the popliteal artery was involved in 56 (27.6%) cases and prior endovascular intervention was performed in 27 (13.3%) cases. Two or more crural run-off vessels were patent in 124 (61.1%). Mean follow-up was 23.2 months ±21.3. At 1, 2 and 3 years, the ffTLR was 90.6±4.2%, 86.4±6.1% and 80.4±8.3%, respectively, and the PP was 85.6±5.0%, 74.2±7.6% and 72.7±8.2%, respectively. Negative prognostic factor for ffTLR and PP was the reference vessel diameter (P=0.001 and P<0.001, respectively). At 1, 2 and 3 years, the AFS was 81.8±6.0%, 75.5±7.1% and 74.2±7.5% respectively; coronary artery disease (P=0.041) and CLTI (P=0.011) resulted negative prognostic factors. CONCLUSIONS: In the real-world practice, around 3/4 of patients were treated for CLTI. The rate of ffTLR is high, and PP is substantially lower. A small vessel diameter (<5 mm) is a negative factor for both ffTLR and PP. The rate of AFS is about 75% at 2 years and CLTI and coronary artery disease are negative prognostic factors.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Doença Arterial Periférica , Humanos , Masculino , Idoso , Paclitaxel/efeitos adversos , Estudos Retrospectivos , Doença Arterial Periférica/cirurgia , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/cirurgia , Isquemia Crônica Crítica de Membro , Grau de Desobstrução Vascular , Resultado do Tratamento , Desenho de Prótese
8.
Acta Biomed ; 92(2): e2021046, 2021 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-33988179

RESUMO

Objectives Type Ia endoleak (EL) after endovascular abdominal aortic repair (EVAR) may be misdiagnosed at completion angiography. Intraoperative contrast-enhanced ultrasound (CEUS) may play a role in early detection and immediate treatment of type Ia EL. Methods From January 2017 to April 2018, patients treated with EVAR underwent intraoperative CEUS. After endograft deployment and ballooning, digital subtraction angiography (DSA) and intraoperative CEUS were performed in a blinded fashion. All cases of type Ia EL at DSA or CEUS were considered. Results Type Ia EL detected at intraoperative CEUS and undetected at DSA was defined in 2 patients. The former was solved with intraoperative re-ballooning; in the latter case, a Palmaz stent deployment was required. The resolution of type Ia EL was detected at intraoperative CEUS control and post-operative computed tomography angiography (CTA). In another patient, the DSA detected a type Ia EL, but intraoperative CEUS reveal a type II EL from lumbar arteries. Post-operative CTA confirm the type II EL. Conclusions The reported cases prove the clinical utility of the intraoperative CEUS, permitting the early identification of 2 type Ia EL. In addition, the intraoperative CEUS is useful in case of dubious type Ia EL at DSA, avoiding unnecessary intraoperative adjunctive procedure or post-operative CTA.


Assuntos
Aneurisma da Aorta Abdominal , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Meios de Contraste , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Humanos , Resultado do Tratamento
9.
Acta Biomed ; 92(S1): e2021149, 2021 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-33944833

RESUMO

BACKGROUND AND AIM: Restenosis after open carotid surgery (OCS) represents an issue that experts are very often facing nowadays, both after carotid endoarterectomy(CEA) and carotid bypass(CB). Yet, even if from one side carotid artery stenting (CAS) is currently recommended by most guidelines as treatment of choice for carotid restenosis after CEA, on the other side little is known regarding the best treatment of restenosis after CB. This clinical case report is aimed to empathize the endovascular treatment as an effective therapeutic option for restenosis after OCS. METHODS: A 75-year-old woman with severe comorbidities was admitted to our Unit for left carotid bypass graft restenosis. One year earlier, the patient had been treated with left carotid bypass grafting in saphenous vein for infectious complications occurred after CEA for symptomatic left carotid stenosis. The patient underwent a carotid Duplex ultrasonography scan (DUS) which showed a hemodynamically significant left carotid venous graft stenosis with peak systolic velocity of 315 cm/sec; in order to assess the grade of the stenosis a computed tomography angiography confirmed the presence of a significant narrowing of left carotid graft. A carotid artery angiography was performed after 20days, reconfirming the presence of a significant left carotid graft stenosis and was successfully treated with 7x40mm self-expanding stent. RESULTS: The patient had an uneventful post-procedural course and was discharged the day after. After six months, the patient underwent a carotid DUS in our outpatient clinic which confirmed the overall graft and stent patency. CONCLUSION: CAS represents a feasible therapeutic option for carotid restenosis in patients treated after CB. This clinical case demonstrates that CAS can be performed with acceptable risks and good early results.


Assuntos
Artérias Carótidas , Ultrassonografia Doppler Dupla , Idoso , Constrição Patológica , Feminino , Humanos , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
10.
Ann Vasc Surg ; 73: 585-588, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33556523

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has proven over the years to be a viable alternative to open surgery. A rare but severe complication is represented by the valve migration. We report a case of TAVI complication due to the loss of the prosthetic valve in the abdominal aorta treated by endovascular approach. METHODS: An 88-year-old patient with severe aortic valve stenosis, symptomatic for dyspnea was proposed for a TAVI because considered at high risk for surgery. During the TAVI procedure, the undeployed device (Edwards SAPIEN 3 - Edwards Lifesciences, Irvine, CA, USA) detached from its delivery system. Several attempts to withdraw the valve fluctuating in the aorta into its supporting system were performed without success. An emergency endovascular treatment was promptly planned to obtain the exclusion from the flow of the embolized valve. Under local anaesthesia, through the percutaneous femoral access already present, a tube aortic endograft (EndurantTM II, Medtronic, Santa Rosa, CA; ETTF2828C70EE) was successfully introduced and deployed in the infrarenal aorta without any related complications. The embolized valve was completely covered by the endgraft and thus fixed to the aortic wall. The first postoperative computer tomography angiography (CTA) confirmed the correct placement of the endograft, the exclusion of the valve from the flow and the patency of the great vessels. No perioperative or postoperative complications were recorded. The patient was discharged on the ninth postoperative day with the indication to a new attempt of TAVI, through transapical access. CONCLUSIONS: In case of intraprocedural loss of an undeplyed valve during TAVI, the valve fixing through endograft deployment in infrarenal aorta is a possible solution.


Assuntos
Aorta Abdominal , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Migração de Corpo Estranho/etiologia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Procedimentos Endovasculares , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/terapia , Humanos , Masculino , Índice de Gravidade de Doença , Resultado do Tratamento
11.
J Endovasc Ther ; 27(6): 922-928, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32729774

RESUMO

Purpose: To report an unusual endovascular technique to manage unfavorable renal artery anatomy encountered in an urgent case of symptomatic postdissection thoracoabdominal aortic aneurysm (TAAA) treated with an off-the-shelf multibranched device. Technique: The technique is demonstrated in a 77-year-old woman who had a history of previous open abdominal aortic aneurysm repair and an emergent procedure to implant a thoracic endograft and an aortic bare Z-stent (PETTICOAT) for acute Stanford type B dissection 7 years prior. The patient presented with a symptomatic, rapidly growing, postdissection TAAA. Endovascular treatment with a Zenith t-Branch was planned. After standard catheterization techniques failed in the left renal artery, a bailout maneuver was utilized to place a "floating" Viabahn stent-graft in the aneurysm sac to create sufficient support to deliver the bridging stent-grafts through the bare stent to the target left renal artery. The procedure was successful in excluding the TAAA and preserving perfusion to all target vessels. No neurological complications occurred. Six-month imaging follow-up confirmed the patency of the bridging stents. Conclusion: Remodeling changes after complex endovascular TAAA procedures often require the use of innovative techniques and materials during secondary procedures. In this case, the presence of a post-PETTICOAT bare aortic stent and hostile target artery anatomy increased the technical difficulty of t-Branch implantation. A "floating" stent-graft could be useful to reach challenging target vessels by providing additional support to bridging stent advancement and deployment.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Artéria Renal/cirurgia , Stents , Idoso , Prótese Vascular , Feminino , Humanos , Desenho de Prótese , Artéria Renal/diagnóstico por imagem , Resultado do Tratamento
12.
Ann Vasc Surg ; 69: 133-140, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32561239

RESUMO

BACKGROUND: The objective of this study is to report an 18-year single-center experience in the surgical and endovascular treatment of arterial complications due to self-injection in drug abuser patients. METHODS: This retrospective single-center study was conducted analyzing a prospectively collected database including all endovascular or surgical procedures performed from January 2007 to December 2019 for any arterial complication due to self-injection in drug abuser patient. Collected data were patient demographic and comorbidity, site and type of arterial lesion (pseudoaneurysm [PA], arteriovenous fistula [AVF]), signs of systemic or local infection, and procedural data (endovascular/surgical treatment). End points were rate of postoperative complications, reintervention rate, limb salvage, and patients' early and long-term survival. RESULTS: In 11 patients (median age 36 years, range 27-47; male 73%), 13 arterial lesions were treated: 10 (77%) PA, 2 (15%) PA associated with AVF, and 1 (8%) isolated AVF. Arterial lesion involved common femoral artery in 5 (38%), superficial femoral artery in 4 (31%), profunda femoral artery in 1 (8%), brachial artery in 2 (15%), and subclavian artery in 1 (8%). Signs of infections were present in 9 of the 13 cases (69%). The treatment was surgical in 11 (85%) cases: 7 interposition graft (6 great saphenous vein, 1 arterial cryopreserved homograft), 2 direct reconstruction, 1 patch plasty with pericardium bovine patch, and 1 arterial ligation. Endovascular treatment was performed in 2 cases: 1 noninfected PA of the superficial femoral artery, and 1 55-mm PA of the postvertebral segment of the right subclavian artery with clinical sign of hemodynamic instability. At 1 month, postoperative complication rate was 8% (one lower limb claudication after superficial femoral artery ligation). Reintervention rate was 8% (interposition graft rupture for repeated self-injections). Limb salvage and patient survival were both 100%. Median follow-up was 5 years (range 1 month to 11.3 years); surgical group: median 8.2 years (range 2 months to 11.3 years); endovascular group: median 3.5 months (range 1-6). During follow-up, neither complications nor reinterventions occurred, and limb salvage was 100% for both groups. At 2, 4, and 6 years, overall estimated patient survival was 91%, 81%, and 81%, respectively, with no procedure-related death. CONCLUSIONS: After surgical or endovascular management of arterial lesions due to self-injection in drug abuser patients, complications occur mainly in the postoperative period. During follow-up, the surgical procedures have low rate of complications, reinterventions, and procedure-related mortality, whereas for the endovascular treatment the mid-term outcomes remain unknown.


Assuntos
Falso Aneurisma/terapia , Fístula Arteriovenosa/terapia , Implante de Prótese Vascular , Usuários de Drogas , Procedimentos Endovasculares , Abuso de Substâncias por Via Intravenosa/complicações , Lesões do Sistema Vascular/terapia , Adulto , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/mortalidade , Fístula Arteriovenosa/diagnóstico por imagem , Fístula Arteriovenosa/etiologia , Fístula Arteriovenosa/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Bases de Dados Factuais , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Itália , Ligadura , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Retratamento , Estudos Retrospectivos , Fatores de Risco , Abuso de Substâncias por Via Intravenosa/mortalidade , Fatores de Tempo , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/mortalidade
13.
J Cardiovasc Surg (Torino) ; 61(6): 729-737, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32241093

RESUMO

BACKGROUND: The aim was to define the prevalence, the evolution and the clinical relevance of the intraprosthetic thrombus deposit (IPT) after endovascular abdominal aortic repair (EVAR). METHODS: Patients treated with EVAR from 2009 to 2017 for abdominal aortic aneurysm were retrospectively considered. Patients with at least one postoperative computed tomography angiography (CTA) performed after a 3-month follow-up were included. Postoperative medical therapy (antiplatelet and/or oral anticoagulant) were recorded. Aorto-iliac anatomical characteristics were measured on pre-operative CTA, while structural and dimensional endograft features were extracted from instructions for use. IPT was defined as intra-endograft thrombus with minimum thickness of 2mm and longitudinally extended for minimum 4 mm, and was assessed in all postoperative CTA. Primary endpoints were freedom from IPT occurrence, risk factors for IPT and evolution of IPT. Secondary endpoints were the prevalence of overall and IPT-related tromboembolic events (TEE: main-body or limb occlusion, distal embolization) during follow-up and its correlation with IPT. RESULTS: Two-hundred twenty-one patients (mean age 76±7 years; male 94%) were included. Deployed endografts were: aorto-biiliac 96%, aorto-uniiliac 3%, aortic tube 1%; dacron 90%, ePTFE 10%. Mean follow-up was 30±25 months. Overall IPT prevalence was 36% (80/221). At 6, 12, 24 and 48 months, overall estimated freedom from IPT occurrence was 86%, 80%, 60% and 52%, respectively (Kaplan-Meier analysis). At Cox uni-variate analysis, postoperative medical therapy has no influence on IPT; aorto-iliac anatomical risk factors for IPT were larger neck diameter (P<0.001), severe neck thrombus (P=0.043), higher percentage of sac thrombus (P<0.001), hypogastric occlusion/coverage (P=0.040); endograft risk factors were proximal diameter ≥30mm (P<0.001), longer main body (P=0.002), dacron fabric (P=0.025), higher ratio between main body area/gate areas and main body area/distal iliac areas (P<0.001 and P<0.001, respectively). At Cox multi-variate analysis, independent risk factors for IPT were larger neck diameter (P=0.003), higher percentage of sac thrombus (P=0.005) and longer main body (P=0.028). During follow-up, IPT disappeared in 14 cases (18%). Overall TEE prevalence was 4% (8/221) and overall estimated freedom from TEE occurrence at 6, 12, 24 and 48 months was 99%, 99%, 95.3%, 94.1%, respectively (Kaplan-Meier analysis). TEE was IPT-related in 5/8 cases (63%). No statistical correlation were found between IPT and TEE. CONCLUSIONS: The development of intraprosthetic graft thrombus (IPT) is a frequent event after EVAR. The risk of IPT is closely correlated with the proximal aortic neck size, the presence of intra-aneurysmal sac thrombus, and the length of the endograft main body. However, there was no statistical correlation between the presence of IPT and TEE.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Oclusão de Enxerto Vascular/epidemiologia , Tromboembolia/epidemiologia , Trombose/epidemiologia , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Bases de Dados Factuais , Procedimentos Endovasculares/instrumentação , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Humanos , Incidência , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Tromboembolia/diagnóstico por imagem , Trombose/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento
14.
Int Angiol ; 39(6): 477-484, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33440925

RESUMO

BACKGROUND: Carotid endarterectomy (CEA) can be performed both under general anesthesia (GA) or local anesthesia (LA) with good results. General anesthesia with preserved consciousness (GAPC) using remifentanil infusion has been already reported in literature and could potentially merge the advantages of GA and LA overcoming the disadvantages of this last technique. Although the good results of GAPC reported in literature, this technique is not widespread in clinical practice. The aim of this study was to report the perioperative results of CEA under GAPC in a large series of consecutive patients. METHODS: This is a retrospective, single center, observational study including all patients treated for CEA under GAPC in our institution between January 2008 and October 2019. Primary endpoints were neurological complications rate, mortality rate in the perioperative period, need to GAPC conversion to GA during surgery and evaluation of the technique with a specific questionnaire regarding patients' satisfaction. Secondary endpoints were myocardial infarction (MI) rate, other perioperative complications rate, rate of intraoperative shunting and need of reintervention in the perioperative period. RESULTS: In the considered period 1290 CEA under GAPC were performed and included in this study. Neurological complications rate was 2.01%, mortality rate in the perioperative period was 0.07%, need of GAPC conversion to GA rate during surgery was 0.46% and patients satisfaction regarding the technique were high with a mean vote of 9.1 in a 0 to 10 scale. In the perioperative period MI rate was 0.23%, other perioperative complications rate was 1.39%, intraoperative shunting rate was 7.1% and reintervention rate after surgery was 2.4%. CONCLUSIONS: CEA under GAPC may combine the advantages of LA and GA, with a very low rate of conversion to GA during surgery and good patients' satisfaction. Moreover, it does not increase neurological, cardiologic and systemic complications. For these reasons CEA under GAPC could represents a valid alternative to GA or LA.


Assuntos
Estenose das Carótidas , Endarterectomia das Carótidas , Anestesia Geral/efeitos adversos , Estenose das Carótidas/cirurgia , Estado de Consciência , Endarterectomia das Carótidas/efeitos adversos , Humanos , Estudos Retrospectivos , Resultado do Tratamento
15.
J Vasc Surg ; 70(6): 1844-1850, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31147132

RESUMO

BACKGROUND: The aim of this study was to evaluate the feasibility and utility of intraoperative contrast-enhanced ultrasound (CEUS) for early detection of endoleaks (ELs) during endovascular abdominal aortic aneurysm repair (EVAR) compared with completion digital subtraction angiography. METHODS: Patients undergoing elective EVAR from January 2017 to April 2018 were consecutively enrolled in this prospective study. After endograft deployment, two-digital subtraction angiography (2DSA) with orthogonal C-arm angulations (anteroposterior and sagittal view) were routinely performed. After the endovascular treatment of clear, high-flow type I/III ELs detected by 2DSA, intraoperative CEUS was carried out in sterile conditions on the surgical field before guidewire removal. Presence and type of EL were evaluated with 2DSA and CEUS. CEUS was performed with the vascular surgeon blinded to the 2DSA findings. The primary end point was the level of agreement between 2DSA and CEUS to detect any type of EL and type II EL. Agreement between two diagnostic methods was calculated using Cohen's kappa. The secondary end point was utility of CEUS for intraoperative adjunctive procedure guidance. RESULTS: Sixty patients were enrolled (mean age, 78 ± 6 years; 90% male). 2DSA revealed 11 ELs (18%; 1 type IA, 10 type II), and CEUS 25 ELs (42%; 2 type IA, 23 type II). 2DSA and CEUS were in agreement in 39 cases (65%; 32 no ELs, 7 type II ELs). CEUS detected 17 ELs not identified by 2DSA (28%; 2 type IA, 15 type II); 2DSA detected three ELs not identified by CEUS (5%; 3 type II). In one case, 2DSA and CEUS detected type II and type IA ELs, respectively. For EL and type II EL detection, Cohen's kappa was 0.255 and 0.250, respectively (both "fair agreement"). Intraoperative adjunctive sac embolization was performed under CEUS control in 4 cases and technical success was 100%. CONCLUSIONS: Intraoperative CEUS during EVAR is feasible and can detect a greater number of ELs than 2DSA, in particular type II ELs. Further studies are necessary to assess the reliability of this intraoperative diagnostic examination. In type II ELs, CEUS may represent an additional, useful tool for intraoperative sac embolization guidance.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Meios de Contraste , Endoleak/diagnóstico por imagem , Procedimentos Endovasculares , Complicações Intraoperatórias/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Diagnóstico Precoce , Estudos de Viabilidade , Feminino , Humanos , Cuidados Intraoperatórios , Masculino , Estudos Prospectivos , Ultrassonografia/métodos
16.
Ann Vasc Surg ; 60: 435-446.e1, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31200054

RESUMO

BACKGROUND: Insufficient evidence is available to recommend a particular strategy for the treatment of type 1a endoleaks (T1aELs) after endovascular abdominal aneurysm repair (EVAR). The aim of this study was to report outcomes of the different treatment modalities proposed for persistent and late-occurring T1aEL after EVAR. METHODS: A systematic review of the literature (database searched: PubMed, Web of Science, Scopus, Cochrane Library) was undertaken until August 2018. Studies about treatment of T1aEL after EVAR (excluding intraoperative treatments during the first EVAR) presenting a series of 5 or more patients with extractable outcome data (at least intraoperative and/or early results) were included. Meta-analyses of proportions were performed using a random-effects model. RESULTS: A total of 39 nonrandomized studies were included (714 patients; 88.1% males, 95% confidence interval [CI] 84.5-91.7; weighted mean age 75.76 years, 95% CI 74.11-77.4). Overall estimated technical success (TS) and clinical success (CS) rates were 93.2% (95% CI 90.5-95.8) and 88.2% (95% CI 84.5-91.9), respectively. Two hundred eighteen patients underwent proximal extension (98.1% TS, 95% CI 96.3-99.8), 131 chimney EVAR (93.9% TS, 95% CI 89.9-97.9), 97 fenestrated EVAR (86.2% TS, 95% CI 77.3-95.1), 90 open conversion (96.5% TS, 95% CI 93-100), 71 embolization (95.2% TS, 95% CI 90.4-100), 35 endostapling (57.2% TS, 95% CI 14.1-100), and 72 conservative treatment (75.4% CS, 95% CI 56.4-94.5). Estimated overall 30-day mortality was 3.2% (95% CI 1.7-4.7), and it was higher for patients undergoing open surgery (6.6%, 95% CI 1.7-11.5). Overall, endoleak resolution during the mean follow-up of 19.4 months (95% CI 15.45-23.36) was maintained in 91% of the patients (95% CI 87.7-94.3). CONCLUSIONS: T1aEL repair appeared generally feasible, with good early to midterm outcomes. Different treatments are available, and the choice should be based on endoleak characteristics, aortic anatomy, and the patient's surgical risk. Conservative treatment and endoleak embolization should be considered only in selected cases, such as low-flow endoleaks and unfit patients.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Embolização Terapêutica , Endoleak/terapia , Procedimentos Endovasculares/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/mortalidade , Tomada de Decisão Clínica , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/mortalidade , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/mortalidade , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Reoperação , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
Acta Biomed ; 90(2): 339-342, 2019 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-31125016

RESUMO

A 56-year man with multiple comorbidities and recent septic embolization presented claudication intermittens (Rutherford3) at right lower limb and complaint in right lower quadrant at abdominal palpation. Duplex and computed tomography angiogram (CTA) showed a 64mm-pseudo-aneurysm (PA) originating from right common iliac artery, occlusion of external iliac and patency of hypogastric artery. An urgent endovascular approach was preferred. By left brachial percutaneous access, coil embolization (Balt SPI™ and Cook MReye™) of hypogastric and common iliac artery and deployment of Amplatzer Vascular PlugII™ into the common iliac artery were performed. Completion angiography showed exclusion of PA. One-day, 3­day and 1-month CTA proofed no vascularization of PA. No fever, no leukocytosis, no signs of infection occurred during follow-up and 10-month CTA showed the complete resolution of pseudoaneurysm.


Assuntos
Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/cirurgia , Embolia/complicações , Procedimentos Endovasculares/métodos , Artéria Ilíaca/cirurgia , Sepse/complicações , Angiografia por Tomografia Computadorizada/métodos , Embolia/diagnóstico por imagem , Embolia/terapia , Seguimentos , Humanos , Artéria Ilíaca/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Medição de Risco , Ruptura Espontânea/diagnóstico por imagem , Ruptura Espontânea/cirurgia , Dispositivo para Oclusão Septal , Resultado do Tratamento
18.
J Vasc Surg ; 70(3): 901-912, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30922745

RESUMO

OBJECTIVE: The revascularization of critical limb ischemia (CLI) in hemodialysis (HD) patients features poor results in terms of patient survival and limb salvage. Recent predictive models in CLI revascularization did not specifically address HD patients. The aim of this study was to define risk factors for clinical success (CS) after revascularization of CLI in HD patients and to transform findings in a prognostic score. METHODS: A retrospective study was conducted of prospectively gathered data, including consecutive HD patients treated for CLI from January 2004 to December 2012. Patients' demographics, comorbidities, CLI stage (Rutherford classification), tissue loss (Texas University Wound classification [TUWC]), and type of revascularization were assessed. End points were CS after revascularization (amputation-free and reintervention-free survival) and a prognostic score for CS based on significant risk factors (multivariable analysis). RESULTS: In the study period, 131 patients (mean age, 70.2 ± 9.9 years; male, 76.3%) with a total of 180 limbs were treated. Endovascular (52.8%), surgical (28.9%), or hybrid (10.6%) revascularization was performed in 163 (90.6%) limbs in 117 patients. The mean (± standard deviation) follow-up was 20.8 ± 21.1 months. Considering revascularized patients, CS was 47.9%, 30.8%, and 17.8% at 6, 12, and 24 months, respectively. On multivariable analysis, age (hazard ratio [HR], 1.03; 95% confidence interval [CI], 1.01-1.05; P = .005), coronary artery disease (CAD; HR, 1.55; 95% CI, 1.04-2.32; P = .032), and TUWC stage D (HR, 1.80; 95% CI, 1.22-2.67; P = .003) were independent negative factors. Type of revascularization had no influence on CS. The score for predicting CS was 0.026 × age (years) + 0.441 × CAD + 0.59 × TUWC stage D. CAD and TUWC stage D were 1 in the presence of disease and 0 in the absence of disease. The score has a significant discrimination power of 75.5% (P = .036), with a best cutoff value of 2.07. Patients with a CS score <2.07 would have a low risk of clinical failure, whereas patients with a CS score >2.07 would have a high risk. There were 31 (26.5%) cases of low-risk score and 86 (73.5%) cases of high-risk score. Cases with low-risk score had a CS at 1 year of 51.6% compared with 23.3% in cases with high-risk score. CONCLUSIONS: CS after revascularization in HD patients remains poor independent of the type of revascularization. A prognostic model based on age, history of CAD, and severity of CLI (TUWC stage D lesion) can estimate an individual's chances of CS and may help in the decision-making process.


Assuntos
Técnicas de Apoio para a Decisão , Procedimentos Endovasculares , Isquemia/cirurgia , Doença Arterial Periférica/cirurgia , Diálise Renal , Insuficiência Renal Crônica/terapia , Procedimentos Cirúrgicos Vasculares , Idoso , Amputação Cirúrgica , Estado Terminal , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Isquemia/diagnóstico , Isquemia/mortalidade , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/mortalidade , Valor Preditivo dos Testes , Intervalo Livre de Progressão , Diálise Renal/efeitos adversos , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/mortalidade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/mortalidade
19.
Acta Biomed ; 90(1): 122-126, 2019 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-30889166

RESUMO

Abdominal aortic aneurysm (AAA) in association with external iliac artery (EIA) occlusion is a rare entity which may limit endovascular aortic aneurysm repair (EVAR) feasibility. We describe the case of an 84-year-old man affected by a 64mm infrarenal inflammatory abdominal aortic aneurysm with complete bilateral occlusion of EIA and patency of both common and internal iliac arteries. The common femoral arteries (CFA) were patent, and the patient was asymptomatic for lower limb claudication. The treatment was performed by EVAR using a bifurcated stent-graft after the recanalization of the left EIA, achieving technical success.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Arteriopatias Oclusivas/cirurgia , Procedimentos Endovasculares/métodos , Artéria Ilíaca , Stents , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Arteriopatias Oclusivas/diagnóstico por imagem , Humanos , Artéria Ilíaca/diagnóstico por imagem , Masculino
20.
J Vasc Surg ; 69(2): 440-447, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30503911

RESUMO

OBJECTIVE: The objective of this study was to investigate the long-term outcome after open repair of inflammatory infrarenal aortic aneurysms. METHODS: A total of 62 patients (mean age, 68.9 ± 8.8 years; 91.9% male) undergoing open surgery for inflammatory aortic aneurysm from 1995 until 2014 in a high-volume vascular center were retrospectively evaluated. The patients' demographics, preoperative and postoperative clinical characteristics, imaging measurements, and procedural data were collected. Study end points were preoperative and postoperative sac diameter, evolution of periaortic fibrosis and development of hydroureteronephrosis detected by computed tomography (CT) scan, and mortality and morbidity after 30 days and at the time of maximum follow-up. RESULTS: The mean abdominal aortic aneurysm diameter was 67.3 ± 16.7 mm. A total of 30 patients (48.4%) were asymptomatic, 27 patients (43.5%) were symptomatic, and 5 patients (8.1%) were treated for ruptured aneurysm. In 25 patients (40.3%), an aorta-aortic tube graft was implanted; in 37 patients (59.7%), an aortic bifurcation graft was used. Median operating time was 208 minutes (range, 83-519 minutes). Median aortic clamping time was 31 minutes (range, 14-90 minutes); in 25 patients (40.3%), suprarenal aortic cross-clamping was necessary. Hydroureteronephrosis was preoperatively diagnosed by CT scan in 16 patients (25.8%), with the need for a ureteral stent in 11 patients (17.7%). Aneurysm- and procedure-associated 30-day mortality was 11.3% (n = 7), with septic multiple organ failure in four patients and cardiac arrest in three patients. The overall perioperative complication rate was 33.9% (n = 21 patients). Median follow-up was 71.0 months (range, 0.2-231.6 months). At 1 year, 2 years, 4 years, and 6 years, overall survival was 83.4%, 79.6%, 79.6%, and 72.6%, respectively. Six patients (9.7%) required a reintervention during follow-up, predominantly aneurysm related and caused by aortoenteric fistula and graft infection (three of five patients). Median maximum thickness of preoperative perianeurysmal inflammation on CT was 10 mm (range, 2-22 mm), which decreased in 15 of 16 (94%) patients with available postoperative CT scans. Postoperative median thickness of perianeurysmal inflammation on CT was 6 mm (range, 0-13 mm). Hydroureteronephrosis persisted in two of nine (22.2%) patients at the end of follow-up. CONCLUSIONS: Surgery in patients with inflammatory abdominal aortic aneurysms is associated with a substantial amount of perioperative complications. After surgery, the perianeurysmal inflammation decreases in most patients on follow-up CT. However, because the inflammatory process does not totally resolve, patients require lifelong surveillance for hydroureteronephrosis and development of aortoenteric fistulas.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aortite/etiologia , Implante de Prótese Vascular , Fibrose Retroperitoneal/etiologia , Idoso , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aortite/diagnóstico por imagem , Aortite/mortalidade , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Angiografia por Tomografia Computadorizada , Feminino , Hospitais com Alto Volume de Atendimentos , Humanos , Hidronefrose/etiologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Fibrose Retroperitoneal/diagnóstico por imagem , Fibrose Retroperitoneal/mortalidade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...